Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/1066| Title: | Nucleate boiling of saturated liquids from a copper coated tube surface |
| Authors: | Prasad, L Agarwal, V K Gupta, S C |
| Keywords: | Nucleate Boiling;Coated surface;Saturated liquids |
| Issue Date: | Jan-2007 |
| Publisher: | CSIR |
| IPC Code: | C09K5/00, B05D1/00 |
| Abstract: | This paper presents an experimental investigation on nucleate pool boiling of saturated liquids, viz. water, methanol and isopropanol on a 26 μm thick copper coated mild steel heating tube at atmospheric and subatmospheric pressures. Enhancement of heat transfer coefficient due to coating is found for all boiling liquids. Thermal performance of a coated tube is evaluated in terms of heat flux and pressure and thereby a criterion for enhancement of heat transfer coefficient for the boiling of saturated liquids on a copper coated tube is established. |
| Page(s): | 85-91 |
| ISSN: | 0971–457X |
| Appears in Collections: | IJCT Vol.14(1) [January 2007] |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJCT 14(1) (2007) 85-91.pdf | 811.35 kB | Adobe PDF | View/Open |