Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/1336Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Tiwari, D C | - |
| dc.contributor.author | Jain, Rajeev | - |
| dc.contributor.author | Sahu, Gaurav | - |
| dc.date.accessioned | 2008-05-21T09:23:02Z | - |
| dc.date.available | 2008-05-21T09:23:02Z | - |
| dc.date.issued | 2007-11 | - |
| dc.identifier.issn | 0022-4456 | - |
| dc.identifier.uri | http://hdl.handle.net/123456789/1336 | - |
| dc.description | 923-927 | en_US |
| dc.description.abstract | Electrochemical behaviour of cefixime has been studied in Britton-Robinson buffer system at composite polymer membrane working electrode and results compared with glassy carbon electrode. A well-defined cathodic diffusion-controlled irreversible peak was observed in entire pH range. The current increases steadily with diffusion scan rate and concentration. | en_US |
| dc.language.iso | en_US | en_US |
| dc.publisher | CSIR | en_US |
| dc.source | JSIR Vol.66(11) [November 2007] | en_US |
| dc.subject | Cefixime | en_US |
| dc.subject | Composite polymer electrode | en_US |
| dc.subject | Cyclic voltammetry | en_US |
| dc.subject | Glassy carbon electrode | en_US |
| dc.title | Voltammetric behaviour of cefixime at a composite polymer membrane electrode | en_US |
| dc.type | Article | en_US |
| Appears in Collections: | JSIR Vol.66(11) [November 2007] | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| JSIR 66(11) (2007) 923-927.pdf | 101.62 kB | Adobe PDF | View/Open |