Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/13463
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKumar, Harish-
dc.contributor.authorSharma, Chitra-
dc.date.accessioned2012-01-25T04:27:53Z-
dc.date.available2012-01-25T04:27:53Z-
dc.date.issued2012-02-
dc.identifier.issn0975-1041 (Online); 0019-5596 (Print)-
dc.identifier.urihttp://hdl.handle.net/123456789/13463-
dc.description86-90en_US
dc.description.abstractThe performance evaluation of the developed ring shaped force transducers of capacity 20 and 50 kN for tension and compression modes has been studied. The force transducers have been metrologically characterized according to the calibration procedures based on the standards ISO 376-2004 and IS 4169-1988 (reaffirmed 2003). The factors contributing to the uncertainty of the force transducers and methodology for computing the uncertainty of force transducers have been discussed. The 50 kN dead weight force machine with uncertainty of force applied (best measurement capability, bmc) ± 0.003% (k = 2) has been used for metrological characterization of force transducers. The force transducers qualify the class 00 per the standard ISO 376-2004 and class 0 as per IS 4169-1988 (reaffirmed 2003), hence, may be used as force transfer standards.en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceIJPAP Vol.50(02) [February 2012]en_US
dc.subjectForce Transduceren_US
dc.subjectIS 4169-1988 (reaffirmed 2003)en_US
dc.subjectISO 376-2004en_US
dc.titlePerformance evaluation of force transducersen_US
dc.typeArticleen_US
Appears in Collections:IJPAP Vol.50(02) [February 2012]

Files in This Item:
File Description SizeFormat 
IJPAP 50(2) 86-90.pdf177.7 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.