Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/14302
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDighe, P M-
dc.contributor.authorKamble, L P-
dc.contributor.authorDas, D-
dc.contributor.authorPithawa, C K-
dc.date.accessioned2012-06-29T09:24:31Z-
dc.date.available2012-06-29T09:24:31Z-
dc.date.issued2012-07-
dc.identifier.issn0975-1041 (Online); 0019-5596 (Print)-
dc.identifier.urihttp://hdl.handle.net/123456789/14302-
dc.description458-461en_US
dc.description.abstractIon chamber sensitive to low energy pulsed X-rays has been developed for area monitoring at the electron accelerators Indus 1 and 2 of Raja Ramanna Centre for Advanced Technology, Indore. Conventional monitors available commercially underestimate the X-ray background because of pulsed nature of the radiation and are not sensitive to X-rays below 100 keV. For this purpose, a high pressure ion chamber made of aluminium with all welded construction has been developed and tested for use in pulsed X-ray background. The chamber has 25 litre sensitive volume, filled with nitrogen at 85 psi and current sensitivity is 12 nA/R/h. The chamber can measure exposure levels from 20 mR/h to 100 mR/h and has uniform energy response within ±12% from 35 keV to 1.25 MeV of X-ray energy. The ion chamber gave more than 86% collection efficiency at 100 mR/h average pulsed X-ray background for 500 V operating voltage. Theoretically evaluated collection efficiency values closely match with the experimentally observed values. The design details and characterisation of the ion chamber under different X-ray energy exposures and collection efficiency estimation for pulsed X-ray background have been studied.en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceIJPAP Vol.50(07) [July 2012]en_US
dc.subjectIon Chamberen_US
dc.subjectPulsed X-rayen_US
dc.subjectElectron acceleratoren_US
dc.subjectArea monitoringen_US
dc.titleLow energy pulsed X-ray ion chamber monitor for accelerator safetyen_US
dc.typeArticleen_US
Appears in Collections:IJPAP Vol.50(07) [July 2012]

Files in This Item:
File Description SizeFormat 
IJPAP 50(7) 458-461.pdf217.7 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.