Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/14890
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSaxena, Reena-
dc.contributor.authorSingh, Suneeti-
dc.date.accessioned2012-11-02T11:04:16Z-
dc.date.available2012-11-02T11:04:16Z-
dc.date.issued2012-11-
dc.identifier.issn0975-0975(Online); 0376-4710(Print)-
dc.identifier.urihttp://hdl.handle.net/123456789/14890-
dc.description1567-1573en_US
dc.description.abstractA rapid and sensitive method for the determination of trace level of Cd(II) in industrial effluents by flame atomic absorption spectroscopy has been developed. The technique is based on the online flow injection preconcentration of Cd(II) ions on a mini column, packed with Amberlite XAD-2 functionalized with xylenol orange. Flow injection variables have been optimized for the determination and quantitative preconcentration of Cd(II). Cd(II) ions are effectively retained on the mini column at pH 5.0. A high sorption capacity of 348 µmol/g of dry resin is obtained and chelating resin can be reused for 70-80 cycles of sorption desorption without any significant change in the sorption capacity. With preconcentration times of 60 s and 120 s at a sample loading flow rate of 5 mL min-1, preconcentration factors of 17 and 32 are obtained. The calibration graph using the preconcentration system for Cd(II) is linear over the concentration range of 0-120 µg L-1. The precision for 5 replicate measurements are 1.68 and 1.12 for the determination of 20 and 50 µg L-1 Cd(II) respectively. The limits of detection obtained are 1.038 and 0.57 µg L-1 for 60 s and 120 s sorption time respectively. A sample throughput of 32 h-1 is obtained with 5 mL of sample solution. Spiked recovery studies in water samples with certified Cd(II) nitrate solution traceable to NIST shows recovery in the range of 98-99 %. The accuracy of the developed online FI-FAAS procedure has been validated by analyzing cadmium(II) in standard reference material (SRM-1643e).en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceIJC-A Vol.51A(11) [November 2012]en_US
dc.subjectFlame atomic absorption spectrometryen_US
dc.subjectOnline preconcentrationen_US
dc.subjectAmberlite XAD-2en_US
dc.subjectXylenol orangeen_US
dc.subjectCadmiumen_US
dc.titleFlow injection preconcentration system using a new functionalized resin for determination of cadmium(II) by flame atomic absorption spectroscopyen_US
dc.typeArticleen_US
Appears in Collections:IJC-A Vol.51A(11) [November 2012]

Files in This Item:
File Description SizeFormat 
IJCA 51A(11) 1567-1573.pdf134.51 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.