Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/14911| Title: | FLUKA simulation of 15 MeV linear accelerator based thermal neutron source for radiography |
| Authors: | Patil, B J Patil, A J Chavan, S T Pethe, S N Krishnan, R Bhoraskar, V N Dhole, S D |
| Keywords: | Neutron radiography;FLUKA simulation;Thermal neutron source;Linear accelerator; -n target |
| Issue Date: | Nov-2012 |
| Publisher: | NISCAIR-CSIR, India |
| Abstract: | FLUKA simulation has been carried out using 15 MeV LINAC to design thermal neutron source for radiography. In this case, a neutron collimator has been designed along with e- target, -n target, moderator and shielding. The -n target has been optimized based on their photonuclear reaction threshold. The moderating properties have been studied for a few light elements to optimize best suitable moderator for radiography system. To get best values of collimator parameters such as collimation ratio, gamma content, neuron fluence rate, cadmium ratio, beam uniformity etc., a FLUKA simulation was carried out. The collimator has been optimized with cadmium lining square cone to capture the scattered thermal neutrons and the collimation ratio to L/D=20. The neutron fluence rate and neutron to gamma ratio of the optimized facility at the object plane is 1.1 105 n cm-2 s-1 and 1.0 105 n cm-2 mR-1. |
| Page(s): | 814-817 |
| ISSN: | 0975-1041 (Online); 0019-5596 (Print) |
| Appears in Collections: | IJPAP Vol.50(11) [November 2012] |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJPAP 50(11) 814-817.pdf | 215.78 kB | Adobe PDF | View/Open |
Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.
-n target
105 n cm-2 s-1 and 1.0