| dc.description.abstract | Batch and column experiments have been performed to qualify the different species of chromium in aqueous sample at pH 5 using ion exchangers and 51Cr radiotracer. Affinity of DOWEX-50 and DOWEX- 1 for cationic and anionic species has been considered the basis of separation. DOWEX-50 is found suitable for speciation of Cr(III), Cr(VI) and organically bound chromium. | en_US |
| dc.language.iso | en_US | en_US |
| dc.publisher | NISCAIR-CSIR, India | en_US |
| dc.rights | CC Attribution-Noncommercial-No Derivative Works 2.5 India | en_US |
| dc.source | IJC-A Vol.38A(05) [May 1999] | en_US |
| dc.title | Estimation of Cr (III), Cr(VI) and organically bound Cr (III) species using ion exchangers & 51Cr radiotracer | en_US |