Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/20646
Title: Determination of Ni(II) and Co(II) by FAAS after preconcentration on modified alumina column
Authors: Shemirani, Farzaneh
Kozani, Reyhaneh Rahnama
Niasari, Masood Salavati
Abkenar, Shiva Dehghan
Jamali, Mohammad Reza
Mirroshandel, Aazam Alsadat
Issue Date: May-2003
Publisher: NISCAIR-CSIR, India
Abstract: A method for the determination of Co(II) and Ni(II) by flame atomic absorption spectrometry after preconcentration on a minicolumn of alumina modified with sodium dodecyl sulfate and schiff's base has been developed. Effects of pH, flow rate, volume of sample solution, capacity of sorbent and interference of foreign ions on the recovery of the analytes have been investigated. Under the optimized conditions (pH = 5; flow rate =15 ml min-1), recovery was greater than 98%. The relative standard deviations (10 replicate analyses) at the 50 ng ml-1 level are 2.5% for Ni(II) and 3.2% for Co(II) and the corresponding limits of detection (3s, n =10) are 0.014 ngml-1 for Ni(II) and 0.007 ng ml-1  for Co(II). The method has been applied for the determination of Ni(II) and Co(II) in natural waters and standard materials.
Page(s): 1086-1088
ISSN: 0975-0975(Online); 0376-4710(Print)
Appears in Collections:IJC-A Vol.42A(05) [May 2003]

Files in This Item:
File Description SizeFormat 
IJCA 42A(5) 1086-1088.pdf267.03 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.