Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/23181Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Basu, Anjan Kumar | - |
| dc.contributor.author | Chattopadhyay, Parimal | - |
| dc.contributor.author | Choudhury, Utpal Roy | - |
| dc.contributor.author | Chakraborty, Runu | - |
| dc.date.accessioned | 2013-11-08T12:13:28Z | - |
| dc.date.available | 2013-11-08T12:13:28Z | - |
| dc.date.issued | 2005-07 | - |
| dc.identifier.issn | 0975-1009 (Online); 0019-5189 (Print) | - |
| dc.identifier.uri | http://hdl.handle.net/123456789/23181 | - |
| dc.description | 646-653 | en_US |
| dc.description.abstract | A hypoxanthine (Hx) biosensor based on immobilized xanthine oxidase (XO) as the bio-component was developed and studied for the rapid analysis of fish (sweet water and marine) and goat meat samples. The biosensor was standardized for the determination of Hx in the range of 0.05 to 2 mM. Crosslinking with glutaraldehyde in presence of BSA as a spacer molecule was used for the method of immobilization. One layer of gelatin (10%) was applied over the immobilized enzyme layer to reduce the leaching out of enzyme from the membrane (cellulose acetate) matrix. The optimum pH of the immobilized system was determined to be 8.5 at 25°C instead 7.0-7.2 for free enzyme system. Km and Vmax values were determined for the immobilized system. The developed sensor was applied to determine the amount of Hx present in fish and meat over a period of time. The stability of the enzyme immobilized membrane was also tested over a period of 30 days. | en_US |
| dc.language.iso | en_US | en_US |
| dc.publisher | NISCAIR-CSIR, India | en_US |
| dc.rights | CC Attribution-Noncommercial-No Derivative Works 2.5 India | en_US |
| dc.source | IJEB Vol.43(07) [July 2005] | en_US |
| dc.subject | Amperometric biosensor | en_US |
| dc.subject | Fish and goat meat | en_US |
| dc.subject | Hypoxanthine | en_US |
| dc.subject | Immobilized XO | en_US |
| dc.title | Development of an amperometric hypoxanthine biosensor for determination of hypoxanthine in fish and meat tissue | en_US |
| dc.type | Article | en_US |
| Appears in Collections: | IJEB Vol.43(07) [July 2005] | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJEB 43(7) 646-653.pdf | 1.83 MB | Adobe PDF | View/Open |
Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.