Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/24354
Title: Corrosion behaviour of sintered ferrous alloys and Ferro-TiC in H2SO4 and NaCl solutions
Authors: Debata, M
Upadhyaya, G S
Issue Date: Jun-2001
Publisher: NISCAIR-CSIR, India
Abstract: The room temperature corrosion behaviour of plain carbon steel Fe-0.5C, low alloy steel Fe-5Cu-0.5C, tool steels ASP 23 and ASP 30, and ferro-TiC cermet was investigated in H2SO4 (0.1-5N) and 0.6 N NaCl solutions by potentiodynamic polarization technique. The study also includes X-ray diffraction, optical microscopy and scanning electron microscopy of the as-received as well as corroded surfaces. Porosities present in Fe-0.5C and Fe-5Cu-0.5C steels were found to be responsible for their poor corrosion resistance. ASP 30 steels were found to exhibit good corrosion resistance as compared to ASP 23 in both the media.
Page(s): 153-160
ISSN: 0975-1017 (Online); 0971-4588 (Print)
Appears in Collections:IJEMS Vol.08(3) [June 2001]

Files in This Item:
File Description SizeFormat 
IJEMS 8(3) 153-160.pdf1.58 MBAdobe PDFView/Open