Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/29347
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSrinivasulu, D-
dc.contributor.authorSastry, B S-
dc.contributor.authorPrakash, G O-
dc.contributor.authorArchana, D N S S-
dc.date.accessioned2014-09-05T07:04:23Z-
dc.date.available2014-09-05T07:04:23Z-
dc.date.issued2014-09-
dc.identifier.issn0975-1084 (Online); 0022-4456 (Print)-
dc.identifier.urihttp://hdl.handle.net/123456789/29347-
dc.description618-621en_US
dc.description.abstractThe objective of the study was to develop a validated, specific and stability-indicating gradient reverse phase liquid chromatographic method for determination of Pioglitazone Hydrochloride along with its impurities in bulk samples. Drug substance was subjected to stress conditions of hydrolysis (acid and base), oxidation, photolytic, humidity and thermal degradation as per International Conference on Harmonization (ICH) to show the stability-indicating power of the method. Significant degradation was observed with alkali and hydrogen peroxide. The impurities were characterized using spectral techniques like IR, 1H NMR and MS. Successful separation of impurities was achieved on C18 ODS (150x4.6 mm) 3.5 µ column using mobile phase consisting of Solvent A: Ammonium acetate buffer and Acetonitrile in the ratio (57:43 v/v) for 0-7 min and Solvent B: Ammonium acetate buffer and Acetonitrile in the ratio (20:80 v/v) at a flow rate of 1.0 ml/min from 7-20 min followed by Solvent A from 20-21 min. The retention times of impurity A, impurity B, impurity C and Pioglitazone were 3.44, 10.65, 17.95 and 8.32 min respectively. The detection wavelength was set at 254 nm with column temperature at 45 ºC. Finally developed method was validated as per ICH guidelines for specificity, linearity, precision and accuracy. en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceJSIR Vol.73(09) [September 2014]en_US
dc.subjectStability Indicatingen_US
dc.subjectLiquid Chromatographyen_US
dc.subjectPioglitazone Hydrochlorideen_US
dc.subjectValidationen_US
dc.titleA new RP-HPLC method for separation and determination of process related impurities in Pioglitazone Hydrochloride APIen_US
dc.typeArticleen_US
Appears in Collections:JSIR Vol.73(09) [September 2014]

Files in This Item:
File Description SizeFormat 
JSIR 73(11) (Erratum).pdfErratum101.54 kBAdobe PDFView/Open
JSIR 73(9) 618-621.pdfMain article103.1 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.