Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/30088
Full metadata record
DC FieldValueLanguage
dc.contributor.authorShah, Purvi-
dc.contributor.authorChampaneri, Naitik-
dc.contributor.authorSolanki, Kamlesh-
dc.contributor.authorThakkar, Vaishali-
dc.contributor.authorPatel, Kalpana-
dc.contributor.authorGandhi, Tejal-
dc.date.accessioned2014-12-24T08:01:43Z-
dc.date.available2014-12-24T08:01:43Z-
dc.date.issued2014-07-
dc.identifier.issn0975-0991 (Online); 0971-457X (Print)-
dc.identifier.urihttp://hdl.handle.net/123456789/30088-
dc.description233-237en_US
dc.description.abstractIn this study, UV spectroscopic and total organic carbon (TOC) Vcsh methods have been developed and validated for the determination of trace amount of ciprofloxacin residues on the manufacturing equipment surfaces and to confirm the efficiency of the cleaning procedure. Ciprofloxacin has been selected on the basis of worst case rating approach. The established limit of contamination value for ciprofloxacin is found to be 36.27 µg that should not be exceeded during consecutive equipment cleaning trials. Ciprofloxacin exhibits good linearity in the range 2-10 µg/mL for UV spectroscopic method and 0.25-1.5 µg/mL for TOC Vcsh analysis. Percentage recovery from spiked stainless steel plate using swab sampling technique is found in the limit of 90.74% and 91.19 % in UV spectroscopic and TOC Vcsh method respectively. Both methods are simple, cheap and less time consuming as well as suitable for quantitative determination of ciprofloxacin on manufacturing equipment surfaces well below the limit of contamination. The validated methods are found to be satisfactory for the demonstration of cleaning validation of ciprofloxacin residue on manufacturing equipment surface. en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceIJCT Vol.21(4) [July 2014]en_US
dc.subjectCiprofloxacinen_US
dc.subjectCleaning validationen_US
dc.subjectManufacturing equipment surfacesen_US
dc.subjectTotal organic carbon Vcsh analysisen_US
dc.subjectUV spectroscopic methoden_US
dc.titleQuantitative determination of ciprofloxacin residues for cleaning validation in manufacturing equipment surfaceen_US
dc.typeArticleen_US
Appears in Collections:IJCT Vol.21(4) [July 2014]

Files in This Item:
File Description SizeFormat 
IJCT 21(4) 233-237.pdf192.59 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.