Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/30870Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Deepak, S | - |
| dc.contributor.author | Venkatram, T | - |
| dc.date.accessioned | 2015-03-12T07:14:22Z | - |
| dc.date.available | 2015-03-12T07:14:22Z | - |
| dc.date.issued | 1998-11 | - |
| dc.identifier.issn | 0975-0991 (Online); 0971-457X (Print) | - |
| dc.identifier.uri | http://hdl.handle.net/123456789/30870 | - |
| dc.description | 351-354 | en_US |
| dc.description.abstract | Several approximate methods for the design of vapor-non-condensable (NC) gas condensers have been proposed, all of which are based on the widely known Colburn-Hougen (CH) method which was considered "tedious" in the pre-computer era. An attempt is made to employ spline equations to correlate design values for executing the CH procedure; and by FEM to determine the temperature along the tube side and shell side of a typical vapor- non-condensable gas condenser. These two are found to be good shortcut methods compatible with the CH procedure. | en_US |
| dc.language.iso | en_US | en_US |
| dc.publisher | NISCAIR-CSIR, India | en_US |
| dc.rights | CC Attribution-Noncommercial-No Derivative Works 2.5 India | en_US |
| dc.source | IJCT Vol.05(6) [November 1998] | en_US |
| dc.title | A modern approach in thermal design of vapor-non-condensable | en_US |
| dc.type | Article | en_US |
| Appears in Collections: | IJCT Vol.05(6) [November 1998] | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJCT 5(6) 351-354.pdf | 321.82 kB | Adobe PDF | View/Open |
Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.