Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/30889
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKulkarni, P B-
dc.contributor.authorJoshi, P V-
dc.contributor.authorBedekar, S D-
dc.date.accessioned2015-03-12T10:13:35Z-
dc.date.available2015-03-12T10:13:35Z-
dc.date.issued1997-01-
dc.identifier.issn0975-0991 (Online); 0971-457X (Print)-
dc.identifier.urihttp://hdl.handle.net/123456789/30889-
dc.description34-38en_US
dc.description.abstractContinuous measurement of H2S concentration around a heavy water plant has been done during summer period using indigenously developed H2S monitor. Diurnal spectrum of hourly mean and maximum H2S levels has been studied and data have been divided into 2 periods of the day. Hourly mean data have been analysed statistically with log normal distribution and hourly maximum data with extreme value distribution. The modal value of hourly maxima for summer period, which works out to be 387 ppb, is much below the TLV of H2S for occupational exposure.en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceIJCT Vol.04(1) [January 1997]en_US
dc.titleThe diurnal variation of H2S levels inside a heavy water plant-Results from field testing of an indigenously made H2S monitoren_US
dc.typeArticleen_US
Appears in Collections:IJCT Vol.04(1) [January 1997]