Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/31205
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKamil, Mohd-
dc.contributor.authorAlam, S S-
dc.contributor.authorAlia, H-
dc.date.accessioned2015-03-26T07:08:33Z-
dc.date.available2015-03-26T07:08:33Z-
dc.date.issued1994-07-
dc.identifier.issn0975-0991 (Online); 0971-457X (Print)-
dc.identifier.urihttp://hdl.handle.net/123456789/31205-
dc.description214-220en_US
dc.description.abstractAn experimental investigation of heat transfer to boiling liquids under natural convective flow through a vertical tube thermosiphon reboiler has been carried out to study the effect of heat flux and liquid submergence on circulation rates. Three test liquids namely: water, methanol and ethylene glycol were used to cover a wide range of boiling points and thermophysical properties. The test section was an electrically heated stainless steel tube 25.56 mm i.d. and 1900 mm length. The uniform heat fluxes in the range of 4.1 to 43 kW/m2 were employed while inlet liquid subcooling varied from 0.5 to 11.6°C. The liquid submergence levels were maintained around 100, 75, 50 and 30%. Circulation rates for all test liquids have been correlated in terms of dimensionless groups.en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceIJCT Vol.01(4) [July 1994]en_US
dc.titleAn experimental study for predicting circulation rates in a reboiler tubeen_US
dc.typeArticleen_US
Appears in Collections:IJCT Vol.01(4) [July 1994]

Files in This Item:
File Description SizeFormat 
IJCT 1(4) 214-220.pdf1.4 MBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.