Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/35511
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDewani, A P-
dc.contributor.authorBakal, R L-
dc.contributor.authorShelke, P G-
dc.contributor.authorChandak, M-
dc.contributor.authorPatra, S-
dc.contributor.authorFarooqui, Salimuddin-
dc.contributor.authorChandewar, A V-
dc.date.accessioned2016-09-29T07:16:06Z-
dc.date.available2016-09-29T07:16:06Z-
dc.date.issued2016-09-
dc.identifier.issn0975-0991 (Online); 0971-457X (Print)-
dc.identifier.urihttp://nopr.niscair.res.in/handle/123456789/35511-
dc.description419-424en_US
dc.description.abstractThe development, validation and application of a simple and reliable gradient high-performance liquid chromatography–diode array detection (HPLC–DAD) procedure for the analysis of a complex mixture containing phenylephrine (PHE), paracetamol (PAR), ambroxol (AMB) and Levocetirizine (LEV) has been carried out . Chromatographic separation of PHE, PAR, AMB and LEV is achieved using a Phenomenex Ultracarb ODS-C18 (4.6×150 mm, 5 µ) column with gradient elution of the mobile phase composed of 10 mM phosphate buffer pH 3.3 and acetonitrile. A three step gradient program has been developed with step-1 elution starting with 2% (by volume) acetonitrile which ramped up linearly to 50% in 10 min, in step-2 reverting back to 20% in 5 min and in step-3 ended to achieve initial concentration of 2% in next 5 min thus contributing a total run time of 20 min. Flow rate maintained throughout the experiment is 1 mL/min. The Diode array detector (DAD) is set at 220 nm for quantification of the analytes based on measuring their peak areas. The retention times for PHE, PAR, AMB and LEV are approximately 4.4, 10.1, 14.00 and 17.90 min respectively. The proposed HPLC procedure is statistically validated with respect to linearity, ranges, precision, accuracy, selectivity and robustness. Calibration curves are found to be linear in 50 to 150% of target analyte in formulation with correlation coefficients > 0.9996. The validated HPLC method is applied successfully with good recoveries of analytes from tablet dosage; no interfering peaks were encountered from the inactive ingredients.en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceIJCT Vol.23(5) [September 2016]en_US
dc.subjectPhenylephrineen_US
dc.subjectParacetamolen_US
dc.subjectAmbroxolen_US
dc.subjectLevocetirizineen_US
dc.subjectGradienten_US
dc.subjectHPLC-DADen_US
dc.subjectTablet dosage formen_US
dc.titleAn gradient HPLC-DAD determination of phenylepherine, paracetamol, ambroxol and levocetrizine in pharmaceutical formulationen_US
dc.typeArticleen_US
Appears in Collections:IJCT Vol.23(5) [September 2016]

Files in This Item:
File Description SizeFormat 
IJCT 23(5) 419-424.pdf142.61 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.