Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/36198
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSubhaprada, G-
dc.contributor.authorKhatri, K-
dc.date.accessioned2016-10-26T06:56:38Z-
dc.date.available2016-10-26T06:56:38Z-
dc.date.issued1991-06-
dc.identifier.issn0975-105X (Online); 0367-8393 (Print)-
dc.identifier.urihttp://nopr.niscair.res.in/handle/123456789/36198-
dc.description287-289en_US
dc.description.abstractGallium doped germanium bolometer cooled to ~ 1.8 K is used as a detector for far-infrared (FIR) astronomical observations by using the TIFR balloon-borne telescope. Since the detector signals are weak (~ 40 nV), an AC coupled, feed-back stabilized, low noise pre-amplifier was designed to amplify these signals. The main features of the pre-amplifier designed are: (1) Frequency range, 5 Hz to 100 Hz; (2) Noise level (referred to input), ~10 nV/Hz1l2 at 10 Hz; (3) Gain stability, ~ 0.04% per °C (+ 25°C to – 20°C); and (4) Input impedence, > 100 MΩ.en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceIJRSP Vol.20(3&4) [June & August 1991]en_US
dc.titleLow noise pre-amplifier for far-infrared observationsen_US
dc.typeArticleen_US
Appears in Collections:IJRSP Vol.20(3&4) [June & August 1991]

Files in This Item:
File Description SizeFormat 
IJRSP 20(3&4) 287-289.pdf192.71 kBAdobe PDFView/Open