http://nopr.niscpr.res.in/handle/123456789/38159| Title: | The design and performance characteristics of a 40 kHz mini pinger transducer for marine applications |
| Authors: | Saksena, T K Jain, S K Gupta, Reeta |
| Issue Date: | Dec-1992 |
| Publisher: | NISCAIR-CSIR, India |
| Abstract: | A mini pinger transducer using radial mode tubular piezoceramic elements of frequency 40 kHz has been developed for intended applications in tracking of small submerged objects. The design criteria to achieve the desired frequency and directional responses for the transducer is discussed. Its performance characteristics such as the source level. transmitting sensitivity and directional response are reported. Electrical impedance characteristics of the transducer and the electro acoustical efficiency obtained are also given. The range of the device activated using 3V battery is estimated to be 50 m. |
| Page(s): | 303-305 |
| ISSN: | 0975-1033 (Online); 0379-5136 (Print) |
| Appears in Collections: | IJMS Vol.21(4) [December 1992] |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJMS 21(4) 303-305.pdf | 144.56 kB | Adobe PDF | View/Open |
Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.