Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/40327Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Mathew, Latha | - |
| dc.contributor.author | Reddy, M L P | - |
| dc.contributor.author | Rao, T Prasada | - |
| dc.contributor.author | Iyer, C S P | - |
| dc.date.accessioned | 2017-02-10T05:48:43Z | - |
| dc.date.available | 2017-02-10T05:48:43Z | - |
| dc.date.issued | 1998-11 | - |
| dc.identifier.issn | 0975-0975(Online); 0376-4710(Print) | - |
| dc.identifier.uri | http://nopr.niscair.res.in/handle/123456789/40327 | - |
| dc.description | 1027-1028 | en_US |
| dc.description.abstract | A differential pulse anodic stripping voltammetric procedure has been described for the determination of trace amounts of endosulfan (an organochlorine pesticide) using static mercury drop electrode. The developed procedure is very sensitive (0.07 to 1.43 ppm) with a detection limit of 14 ppb. It has been used for the determination of endosulfan in formulations and tomato samples in aqueous ethanolic medium. | en_US |
| dc.language.iso | en_US | en_US |
| dc.publisher | NISCAIR-CSIR, India | en_US |
| dc.rights | CC Attribution-Noncommercial-No Derivative Works 2.5 India | en_US |
| dc.source | IJC-A Vol.37A(11) [November 1998] | en_US |
| dc.title | Differential pulse anodic stripping voltammetric determination of endosulfan | en_US |
| dc.type | Article | en_US |
| Appears in Collections: | IJC-A Vol.37A(11) [November 1998] | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJCA 37A(11) 1027-1028.pdf | 228.86 kB | Adobe PDF | View/Open |
Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.