Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/5101
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJaiswal, Shiv Kumar-
dc.contributor.authorOjha, V N-
dc.contributor.authorSingh, Ajeet-
dc.date.accessioned2009-07-03T13:40:09Z-
dc.date.available2009-07-03T13:40:09Z-
dc.date.issued2005-09-
dc.identifier.issn0975-1084 (Online); 0022-4456 (Print)-
dc.identifier.urihttp://hdl.handle.net/123456789/5101-
dc.description666-673en_US
dc.description.abstractIn the present paper, calibration of precision DC high current source (> 2 A and up to 100 A), widely used in industries and research, has been discussed as case studies of transconductance amplifier and precision power supply calibration. Since transconductance amplifier requires boosting device for its operation, therefore effect of boosting device was added as an additional component of uncertainty. The various sources of uncertainty in measurement and their estimation based on Type A and Type B method as per ISO ‘GUM’ document are discussed in detail. The results are reported at coverage factor k=2 for approx 95% confidence level. The standards used for calibration are traceable to the ‘National Standards’ and their uncertainties were evaluated prior to use to avoid variation in results due to drift.en_US
dc.language.isoen_USen_US
dc.publisherCSIRen_US
dc.relation.ispartofseriesG01N37/00en_US
dc.sourceJSIR Vol.64(09) [September 2005]en_US
dc.subjectCalibrationen_US
dc.subjectUncertainty in measurementen_US
dc.subjectCurrent shunten_US
dc.subjectDigital voltmeteren_US
dc.titleEstimation of uncertainty in measurement in precision calibration of DC high current source up to 100 Aen_US
dc.typeArticleen_US
Appears in Collections:JSIR Vol.64(09) [September 2005]

Files in This Item:
File Description SizeFormat 
JSIR 64(9) 666-673.pdf185.14 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.