Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/52715Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lu, Yao | - |
| dc.contributor.author | Fu, Shaoju | - |
| dc.contributor.author | Hu, Bing | - |
| dc.contributor.author | Cheng, Ge | - |
| dc.contributor.author | Li, Nannan | - |
| dc.contributor.author | Zhou, Shuanglin | - |
| dc.date.accessioned | 2019-12-17T08:27:44Z | - |
| dc.date.available | 2019-12-17T08:27:44Z | - |
| dc.date.issued | 2019-12 | - |
| dc.identifier.issn | 0975-1025 (Online); 0971-0426 (Print) | - |
| dc.identifier.uri | http://nopr.niscair.res.in/handle/123456789/52715 | - |
| dc.description | 404-410 | en_US |
| dc.description.abstract | Composite meshes of different types have been prepared and used for tissue repair in pelvic floor disorder. An interlocking texture mesh (inter-mesh) and a membrane coated mesh (electro-mesh) have been used based on their structural property and biocompatibility. The proportion of degradation material in inter-mesh (69.6%) is found extremely higher than that of electro-mesh (3.22%), thus leading to higher product weight (65.50±2.31 g/m2) and thickness (0.500±0.025 mm). After 4 weeks of implantation in animal experiment, inter-mesh with surrounding tissues is observed to have higher breaking strength in tensile behavoir and better flexibility. Tissues on inter-mesh are found to grow faster with larger thickness (0.76±0.033 mm). The surface area loss of inter-mesh (2.49±0.25%) is much less than that of electro-mesh (7.49±0.63 %) within the first 2 weeks of implantation. However, the material’s degradation is accelerated after 2 weeks, leading to a higher shrinkage of 13.12±1.48 %. | en_US |
| dc.language.iso | en_US | en_US |
| dc.publisher | NISCAIR-CSIR, India | en_US |
| dc.rights | CC Attribution-Noncommercial-No Derivative Works 2.5 India | en_US |
| dc.source | IJFTR Vol.44(4) [December 2019] | en_US |
| dc.subject | Biocompatibility | en_US |
| dc.subject | Electrospinning | en_US |
| dc.subject | Elctro-mesh | en_US |
| dc.subject | Interlocking texture | en_US |
| dc.subject | Inter-mesh | en_US |
| dc.subject | Pelvic floor repair | en_US |
| dc.subject | Polypropylene mesh | en_US |
| dc.subject | Polylactic acid mesh | en_US |
| dc.title | Novel composite meshes to evaluate their structural property and in vivo biocompatibility for tissue repair | en_US |
| dc.type | Article | en_US |
| Appears in Collections: | IJFTR Vol.44(4) [December 2019] | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJFTR 44(4) 404-410.pdf | 718.53 kB | Adobe PDF | View/Open |
Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.