Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/54472| Title: | Fluorescence quenching and measurement of captopril in pharmaceuticals |
| Authors: | Chen, Yahong Chang, Weixiao Zhu, Xue Wang, Ruiyong Tian, Fengshou |
| Keywords: | Captopril;Enzyme-catalyzed product;Fluorescence quenching |
| Issue Date: | Jun-2020 |
| Publisher: | NISCAIR-CSIR, India |
| Abstract: | The mechanism of fluorescence quenching of the product S in the presence of captopril was studied. The maximum emission wavelength of the product S was at 405 nm with the excitation wavelength at 316 nm. It was found that the fluorescence quenching of product S was of a static one and the binding constant (K) was 9.29 × 106 J mol-1. A linear relationship was found between the relative fluorescence intensity of the product S-captopril system and the concentration of captopril. Under optimum conditions, the linear range of the calibration curve for captopril was 2~160 μg L-1 with a correlation coefficient of 0.9926 and a detection limit of 0.1 μg L-1. The relative standard deviation (RSD) was 3.60%. The analytical results of the pharmaceuticals obtained by this novel method agreed quite well with those obtained by the KIO3 titrimetry. |
| Page(s): | 270-276 |
| ISSN: | 0975-0959 (Online); 0301-1208 (Print) |
| Appears in Collections: | IJBB Vol.57(3) [June 2020] |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJBB 57(3) 270-276.pdf | 1.64 MB | Adobe PDF | View/Open |