Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/55050
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRao, K. Tirumala-
dc.contributor.authorRao, L. Vaikunta-
dc.contributor.authorKandepi, V. V. Krishna Mohan-
dc.date.accessioned2020-09-01T05:37:39Z-
dc.date.available2020-09-01T05:37:39Z-
dc.date.issued2020-08-
dc.identifier.issn0975-0975(Online); 0376-4710(Print)-
dc.identifier.urihttp://nopr.niscair.res.in/handle/123456789/55050-
dc.description1148-1157en_US
dc.description.abstractA simple, rapid, sensitive, specific, eco-friendly and stability-indicating linear gradient liquid chromatographic method (RP-UHPLC) for simultaneous estimation of assay and its related compounds in Meropenem API samples is developed and validated. Chromatographic separation was achieved on Zorbax Eclipse plus C18, (100 x 4.6) mm, 3.5 µm RRLC short column and 10 mM potassium dihydrogen orthophosphate is used as buffer, buffer solution used as eluent A and buffer and acetonitrile combination 30: 70 v/v ratio used as eluent B and Agilent RRLC (UHPLC) system is used for analysis. The mobile phase flow rate was 1.0 ml/min, and the eluted compounds have been monitored at 220 nm for related substance method and 290 nm for assay method. Excellent resolution is obtained between Meropenem and its related compounds which were eluted within 10 min. The correlation co-efficient(r) is > 0.995 for both the methods from linearity data and percentage of recovery is 98.0 to 102.0 and 80.0 to 120.0 % for assay method and for related substance method, respectively. Sensitivity of the method is found to be less than 0.316 µg/ml. Peak homogeneity data for Meropenem in the chromatograms from the stressed samples are obtained by using photodiode array detector demonstrated the specificity of the method for analysis of Meropenem in presence of the degradation compounds. The performance of the method is validated according to the present ICH guidelines for specificity, limit of detection, limit of quantification, linearity, accuracy, precision, and robustness.en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceIJC-A Vol.59A(08) [August 2020]en_US
dc.subjectMeropenemen_US
dc.subjectRelated substancesen_US
dc.subjectAssayen_US
dc.subjectMethod developmenten_US
dc.subjectValidationen_US
dc.subjectUHPLCen_US
dc.subjectRRLCen_US
dc.titleA novel validated eco-friendly RP-UHPLC method for assay and related substances in Meropenemen_US
dc.typeArticleen_US
Appears in Collections:IJC-A Vol.59A(08) [August 2020]

Files in This Item:
File Description SizeFormat 
IJCA 59A(8) 1148-1157.pdf561.92 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.