Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/57941
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMahmoud, Gouda M-
dc.contributor.authorAggag, Gamal A-
dc.contributor.authorGelany, Shaker A-
dc.date.accessioned2021-08-23T11:44:08Z-
dc.date.available2021-08-23T11:44:08Z-
dc.date.issued2021-08-
dc.identifier.issn0975-0959 (Online); 0301-1208 (Print)-
dc.identifier.urihttp://nopr.niscair.res.in/handle/123456789/57941-
dc.description537-543en_US
dc.description.abstractThis paper presents two mechanisms for load cell calibrations. The first technique was to use deadweight to generate the required reference load (Applied load). The second method was to use a pressure piston gauge to generate the required calibration force. In both mechanisms, the setup and procedures are described. For verification the results of these methods were compared with international metrology institute calibration results. It was found that deadweight method is the most accurate and the piston gauge is the most realistic at high force values.en_US
dc.language.isoenen_US
dc.publisherNIScPR-CSIR, Indiaen_US
dc.sourceIJPAP Vol.59(08) [August 2021]en_US
dc.subjectForce transduceren_US
dc.subjectRepeatabilityen_US
dc.subjectReproducibilityen_US
dc.subjectCreepen_US
dc.subjectPiston gaugeen_US
dc.subjectPressure balanceen_US
dc.titleAn Investigation on the Techniques used in Force Calibration using Deadweights and Pressure Piston Gaugeen_US
dc.typeArticleen_US
Appears in Collections:IJPAP Vol.59(08) [August 2021]

Files in This Item:
File Description SizeFormat 
IJPAP 59(8) 537-543.pdf846.2 kBAdobe PDFView/Open