| dc.contributor.author | Pakrudheen, Iqbal | - |
| dc.contributor.author | Bathinapatla, Ayyappa | - |
| dc.contributor.author | Murugan, Eagambaram | - |
| dc.date.accessioned | 2022-11-21T11:32:44Z | - |
| dc.date.available | 2022-11-21T11:32:44Z | - |
| dc.date.issued | 2022-11 | - |
| dc.identifier.issn | 0975-0991 (Online); 0971-457X (Print) | - |
| dc.identifier.uri | http://nopr.niscpr.res.in/handle/123456789/60875 | - |
| dc.description | 668-677 | en_US |
| dc.description.abstract | A novel enzyme-free electrochemical sensor has been developed based on the prussian blue nanoparticles (PBNPs) loaded on a glassy carbon electrode (GCE) modified with amphiphilic poly(propylene imine) dendrimer (PBNPs/APPI(G3)/GCE) for sensing of hydrogen peroxide. The structural characterization of the newly synthesized template of APPI(G3) has been carried out by fourier transform infrared spectroscopy (FT-IR), nuclear magnetic resonance spectroscopy (NMR) and matrix-assisted laser desorption/ionization coupled to time-of-flight mass spectroscopic (MALDI-TOF) studies. The electrodeposition and stabilization of PBNPs on the APPI(G3) template have been characterized by cyclic voltammetry and field emission scanning electron microscope (FESEM) studies. From the results, a homogeneous distribution of PBNPs with an average size of 50-100 nm on the APPI(G3) modified electrode surface has been observed. The PBNPs/APPI(G3)/GCE has shown an excellent performance towards the detection of hydrogen peroxide with ample electrochemical, mechanical stability, and good sensitivity to the other prussian blue-based H2O2 sensors. The developed sensor exhibit a linear response for H2O2 reduction over the concentration range of 100 to 1000 μM with a detection limit of 60 μM (S/N = 3), and sensitivity of 0.012 AM-1 using the amperometric method. The obtained results have shown that PBNPs/APPI(G3)/GCE can be a promising electrochemical sensing platform for the detection of H2O2 in chemical and biological analysis. | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | NIScPR-CSIR, India | en_US |
| dc.source | IJCT Vol.29(6) [November 2022] | en_US |
| dc.subject | Amphiphilic dendrimer | en_US |
| dc.subject | Electrochemical sensor | en_US |
| dc.subject | Hydrogen peroxide | en_US |
| dc.subject | Prussian blue | en_US |
| dc.title | Amphiphilic dendrimer loaded prussian blue nanoparticle for the detection of hydrogen peroxide | en_US |
| dc.type | Article | en_US |
| dc.identifier.doi | https://doi.org/10.56042/ijct.v29i6.67398 | en_US |
| Appears in Collections: | IJCT Vol.29(6) [November 2022] | |