Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/61407Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Padmanaban, Sivakumar | - |
| dc.contributor.author | Marrapu, Vijay K | - |
| dc.contributor.author | Sahoo, Rabindra | - |
| dc.contributor.author | P, Siva Jyothi | - |
| dc.contributor.author | Tyagi, Hemant | - |
| dc.date.accessioned | 2023-02-21T09:44:12Z | - |
| dc.date.available | 2023-02-21T09:44:12Z | - |
| dc.date.issued | 2023-02 | - |
| dc.identifier.issn | 2583-1321 (Online); 0019-5103 (Print) | - |
| dc.identifier.uri | http://nopr.niscpr.res.in/handle/123456789/61407 | - |
| dc.description | 153-157 | en_US |
| dc.description.abstract | A new method has been developed for the estimation of an antistatic agent glycerol monostearate (GMS) in polypropylene (PP) over gas chromatography coupled with flame ionization detector (GC-FID). In the present work, selection of suitable sample specimen, sample weight, solvent mixture, extraction time, and temperature have been identified for the extraction of GMS in the PP resin. In-house polypropylene pellet has been used for study and the GMS extorted into n-hexane-ethyl acetate and quantified using GC-FID over 100% Dimethyl polysiloxane column. The method limit of detection is 1 mg/L and the limit of quantification is 5-750 mg/kg in PP resin with a correlation coefficient greater than 0.999. This method is accurate and has not found any interference with other co additives used in the propylene. | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | NIScPR-CSIR, India | en_US |
| dc.source | IJC Vol.62(02) [Feb 2023] | en_US |
| dc.subject | Polypropylene | en_US |
| dc.subject | Polymer additives | en_US |
| dc.subject | Solvent extraction | en_US |
| dc.subject | Glycerol mono stearate | en_US |
| dc.subject | Gas chromatography with flame ionization detection (GC-FID) | en_US |
| dc.title | Extraction and estimation of antistatic agent glycerol monostearate in polypropylene by gas chromatography coupled with flame ionisation detector | en_US |
| dc.type | Article | en_US |
| dc.identifier.doi | https://doi.org/10.56042/ijc.v62i2.61078 | en_US |
| Appears in Collections: | IJC Vol.62(02) [Feb 2023] | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJC_62 (02) 153-157.pdf | 511.43 kB | Adobe PDF | View/Open | |
| IJC 62(02)153-157 Supp. Info.pdf | 485.33 kB | Adobe PDF | View/Open |
Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.