Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/62705
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKumar, Amit-
dc.contributor.authorSarangi, Arjamadutta-
dc.contributor.authorSingh, D K-
dc.contributor.authorDash, Sukanta-
dc.contributor.authorMani, Indra-
dc.date.accessioned2023-10-06T06:19:45Z-
dc.date.available2023-10-06T06:19:45Z-
dc.date.issued2023-10-
dc.identifier.issn0022-4456 (Print); 0975-1084 (Online)-
dc.identifier.urihttp://nopr.niscpr.res.in/handle/123456789/62705-
dc.description1091-1099en_US
dc.description.abstractAccurate measurement of flow depth in an open channel on a real-time basis is the prime factor leading to more accurate quantification of discharge by the flow measuring device. The aim of present study was to evaluate the ultrasonic sensors (viz. HC-SR04 and JSN-SR04T) for depth of flow and corresponding discharge rate measurement in irrigation channel of canal command. The effect of ambient temperature on ultrasonic sensors was also investigated for irrigation channel hydraulic response measurement. It was observed that the performance of calibrated and temperature compensated sensors was better than the uncalibrated ones. Moreover, the performance of JSN-SR04T was better with mean absolute deviation (MAD: 0.21 ± 0.01cm), root mean square error (RMSE: 0.82 ± 0.01) and mean absolute percentage error (MAPE: 0.46 ± 0.09) compared to HC-SR04 sensor with MAD (0.36 ± 0.07), RMSE (0.43 ± 0.08) and MAPE (1.54 ± 0.82), respectively. Hence, JSN-SR04T ultrasonic sensor was used in the developed sensing system for the measurement of flow depth. It was observed that the system measured flow rate when compared with the observed flow resulted in prediction error estimate MAD (0.13 ± 0.05 lps), RMSE (0.16 ± 0.05) and MAPE (2.09 ± 1.16) and coefficient of determination (R2: 0.99) for flow rate ranging from 2 to 20 lps. Overall, the study resulted in the development of a novel and economically viable open channel digital flow sensing system to measure discharge rate passing through the flume. The developed sensing system will assist stakeholders in enhancing surface irrigation water use efficiency in canal commands.en_US
dc.language.isoenen_US
dc.publisherNIScPR-CSIR,Indiaen_US
dc.sourceJSIR Vol.82(10) [October 2023]en_US
dc.subjectAgricultureen_US
dc.subjectCommand areaen_US
dc.subjectIrrigation channelen_US
dc.subjectSurface irrigationen_US
dc.subjectWater use efficiencyen_US
dc.titleEvaluation of Ultrasonic Sensor for Flow Measurement in Open Channelen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.56042/jsir.v82i10.2613en_US
Appears in Collections:JSIR Vol.82(10) [October 2023]

Files in This Item:
File Description SizeFormat 
JSIR 82(10) 1091-1099.pdf1.17 MBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.