Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/63326| metadata.dc.identifier.doi: | https://doi.org/10.56042/ijftr.v48i4.7638 |
| Title: | Comparative analysis of residual pressure drop behavior between electrostatically assisted flat based and pilot pulse jet filter unit using conductive filter media |
| Authors: | Dutta, Sudev Mukhopadhyay, Arunangshu Choudhary, A K Reddy, C C |
| Keywords: | Conductive filter media;Correlation behavior;Dust charge;Dust concentration;Residual pressure drop |
| Issue Date: | Dec-2023 |
| Publisher: | NIScPR-CSIR, India |
| Abstract: | The present study aims at comparing the pressure drop behavior of three different needle-punched polyester conductive materials, viz. PTFE coated media, stainless steel fibre blended with PET media and stainless steel fibre scrim media. This comparison is done on a laboratory-based electrostatically assisted pulse-jet flat media test rig with the pilot filter unit, which is closer to the industrial set-up. The materials are investigated using fly ash aerosol, pre-charged at three different levels of charge, viz. 4 kV, 8 kV and 12 kV. The interpretations reveal that the flat media test rig is observed to exhibit lower residual pressure drop for all the investigated materials. |
| Page(s): | 380-387 |
| ISSN: | 0975-1025 (Online); 0971-0426 (Print) |
| Appears in Collections: | IJFTR Vol.48(4) [December 2023] |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJFTR 48(4) 380-387.pdf | 1.38 MB | Adobe PDF | View/Open |
Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.