Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/63326
metadata.dc.identifier.doi: https://doi.org/10.56042/ijftr.v48i4.7638
Title: Comparative analysis of residual pressure drop behavior between electrostatically assisted flat based and pilot pulse jet filter unit using conductive filter media
Authors: Dutta, Sudev
Mukhopadhyay, Arunangshu
Choudhary, A K
Reddy, C C
Keywords: Conductive filter media;Correlation behavior;Dust charge;Dust concentration;Residual pressure drop
Issue Date: Dec-2023
Publisher: NIScPR-CSIR, India
Abstract: The present study aims at comparing the pressure drop behavior of three different needle-punched polyester conductive materials, viz. PTFE coated media, stainless steel fibre blended with PET media and stainless steel fibre scrim media. This comparison is done on a laboratory-based electrostatically assisted pulse-jet flat media test rig with the pilot filter unit, which is closer to the industrial set-up. The materials are investigated using fly ash aerosol, pre-charged at three different levels of charge, viz. 4 kV, 8 kV and 12 kV. The interpretations reveal that the flat media test rig is observed to exhibit lower residual pressure drop for all the investigated materials.
Page(s): 380-387
ISSN: 0975-1025 (Online); 0971-0426 (Print)
Appears in Collections:IJFTR Vol.48(4) [December 2023]

Files in This Item:
File Description SizeFormat 
IJFTR 48(4) 380-387.pdf1.38 MBAdobe PDFView/Open