Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/66753
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVerma, Rinki-
dc.contributor.authorAgrahari, Ravinder Kumar-
dc.contributor.authorPathak, Krishna Kant-
dc.contributor.authorPathak, Virendra-
dc.date.accessioned2025-11-11T10:04:10Z-
dc.date.available2025-11-11T10:04:10Z-
dc.date.issued2025-08-
dc.identifier.issnISSN: 0975-1017 (Online); 0971-4588 (Print)-
dc.identifier.urihttp://nopr.niscpr.res.in/handle/123456789/66753-
dc.description425-437en_US
dc.description.abstractAssessing non-structural elements' vulnerability to acceleration has relied on peak horizontal floor acceleration. Given the dynamic nature of structures, estimates for forces acting on elements like mechanical, electrical, or architectural components have been crucial. The amplification factor for these non-structural components has been affected not just by building height but also by the structural support conditions. This study has examined five distinct building models spanning 2, 4, 6, 8, and 10 stories. The models have been analysed using the nonlinear time history analysis method under various near-field Chi-chi earthquake scenarios (ranging from 0.01g to 0.067g, 0.067g to 0.2g, and 0.2g to 0.32g). This analysis has aimed to determine the acceleration amplification factor (Ω), defined as the ratio of peak floor acceleration to peak ground acceleration (PGA), for both fixed and pinned support conditions. A disparity has emerged after comparing the actual acceleration amplification values under fixed and pinned support conditions with those from previous models. While some models have performed adequately under fixed support conditions, others have yielded accurate results under pinned support conditions. Consequently, there has been no singular formula capable of effectively accommodating both support conditions across the varying ranges of ground motion.en_US
dc.language.isoenen_US
dc.publisherNIScPR-CSIR, Indiaen_US
dc.sourceIJEMS Vol.32(04) Augusten_US
dc.subjectAcceleration amplification factoren_US
dc.subjectNon-structural componentsen_US
dc.subjectPeak floor accelerationen_US
dc.subjectTime history analysisen_US
dc.titleSeismic acceleration amplification factor under fixed and pin supported RC frame buildingen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.56042/ijems.v32i04.15705en_US
Appears in Collections:IJEMS Vol.32(04) August

Files in This Item:
File Description SizeFormat 
IJEMS 32(2) 425-437.pdf3.82 MBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.