Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/7014| Title: | Holdup measurement in a gas-liquid ejector for a sodium chloride-air system |
| Authors: | Raghuram, P T Das, T R |
| Keywords: | Holdup measurement;Ejector;Radiological method;Gamma ray attenuation;Non-reactive system |
| Issue Date: | Mar-2006 |
| Publisher: | CSIR |
| IPC Code: | F04B47/00 |
| Abstract: | Holdup measurements have been carried out experimentally using gamma ray attenuation method in a gas liquid ejector for a sodium chloride-air system. The measured values are compared with the theoretically predicted values based on feed calculations. Holdup as a function of the liquid flowrate and also its distance from the nozzle of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those of air-water system. |
| Page(s): | 144-148 |
| ISSN: | 0975-0991 (Online); 0971-457X (Print) |
| Appears in Collections: | IJCT Vol.13(2) [March 2006] |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJCT 13(2) 144-148.pdf | 157.5 kB | Adobe PDF | View/Open |