dc.description.abstractRecently, dc high voltage laboratory has been established at National Physical Laboratory, India (NPLI) for calibration of high voltage (HV) equipment. High Voltage resistive divider is the heart of dc high voltage measurements. The traceability of HV measurements is directly related to divider’s traceability to Josphson voltage standard, which is the primary standard of dc voltage. In-house calibration of HV divider using traceable dc calibrator and 10 V reference standard has been discussed in the present paper. The overall uncertainty of measurement has also been calculated and is about 10 ppm.en_US
dc.language.isoen_USen_US
dc.publisherCSIRen_US
dc.relation.ispartofseriesG12B13/00en_US
dc.sourceIJPAP Vol.44(06) [June 2006]en_US
dc.subjectCalibrationen_US
dc.subjectHigh voltage measurementen_US
dc.subjectTraceabilityen_US
dc.title Traceability of 100 kV dc high voltage measurements at NPL, India en_US