Please use this identifier to cite or link to this item:
http://nopr.niscpr.res.in/handle/123456789/9319| Title: | Thermal post-buckling behaviour of tapered columns—A simple solution |
| Authors: | Raju, K Kanaka Rao, G Venkateswara |
| Issue Date: | Dec-2004 |
| Publisher: | CSIR |
| IPC Code: | Int. Cl.7 F16S, E04C 3/30 |
| Abstract: | The applicability of a simple method proposed earlier by the authors to predict the thermal post-buckling behaviour of structural elements has been demonstrated in this paper for the case of tapered columns. Numerical results are presented to show the accuracy of the method along with comparable finite element results. Both depth and diameter tapered columns are considered with simply supported and clamped boundary conditions. |
| Page(s): | 460-464 |
| ISSN: | 0975-1017 (Online); 0971-4588 (Print) |
| Appears in Collections: | IJEMS Vol.11(6) [December 2004] |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| IJEMS 11(6) 460-464.pdf | 165.13 kB | Adobe PDF | View/Open |
Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.