| dc.contributor.author | Irimescu, Adrian | - |
| dc.contributor.author | Lelea, Dorin | - |
| dc.date.accessioned | 2010-07-02T07:36:50Z | - |
| dc.date.available | 2010-07-02T07:36:50Z | - |
| dc.date.issued | 2010-07 | - |
| dc.identifier.issn | 0975-1084 (Online); 0022-4456 (Print) | - |
| dc.identifier.uri | http://hdl.handle.net/123456789/9859 | - |
| dc.description | 548-553 | en_US |
| dc.description.abstract | This study proposes an integrated model for thermodynamic analysis of gas turbine powered cogeneration systems,covering simple cycle and overall cogeneration efficiency, load control by using inlet guide vanes, inlet fogging and supplementaryfiring. The model can be further developed for other applications (air cooling, steam injection, and trigeneration ofpower, heat and cooling). | en_US |
| dc.language.iso | en_US | en_US |
| dc.publisher | CSIR | en_US |
| dc.source | JSIR Vol.69(07) [July 2010] | en_US |
| dc.subject | Cogeneration | en_US |
| dc.subject | Gas turbine | en_US |
| dc.subject | Thermodynamic analysis | en_US |
| dc.title | Thermodynamic analysis of gas turbine powered cogeneration systems | en_US |